1. Introduction:

"Hydrolite" ZGC151FD is a sort of cation exchange resin that has sulfonic group (-SO3H) in the styrene-diethylene benzene copolymer with macroporous structure. Because of its macroporous matrix, it has better ability to anti-attrition, anti-permeate and anti-oxidant.

After the special purify treatment, ZGC151FD meets with food grade requirements, it has great physical and chemical stability, high purity level, and with minimum metals and residuals left in the pore of resins and no organic dissolved matters, thus especially suitable for potable water treatment, decoloration and desalination of food industries (e.g.: starch sugar, tartaric acid, beer, sorbitol, xylitol, amino acid, citric acid, lactic acid etc.)

Note: ZGC151FD (ZG Export Product Type) is D001FD (ZG Domestic Product Type)

2. Physical and Chemical Properties:

Items

Index

Appearance

Brown Opacity Beads

Matrix

Styrene-DVB

Functional Group

(-SO3H)

Ionic Form

Na+

Moisture Content %

45.0 ~ 55.0

Capacity based on weight mmol/g

≥ 4.35

Capacity based on volume mmol/ml

≥ 1.70

Shipping Weight g/ml

1.25~1.28

True Density (Wet) g/ml

0.75~0.85

Particle Size Range %

(0.45~1.25mm)≥ 95.0

Low Limited %

(<0.45mm) ≤ 1.0

Uniform Coefficient

≤ 1.60

Whole Beads %

≥ 90.0

3. Reference:

Items

Reference

Height of Resin Bed m

1.5~3.0

Back Wash Space %

50~100

Regenerant Agent

HCl

Regenerant Density %

4~5

Regenerant Dosage m3/m3-R

2.0~2.5

Regenerate Contact Time min

40~60

Replacement Time min

≥ 30

Rinse Flow Rate m/h

15~20

Converse Swelling %

≤ 8.0

Operation Temperature°C

≤ 80

Temperature Limited °C

120

pH Range

0~14

4. Operation Guide

Sugar Recovery

Clean Water

Flow Rate(BV/h)

Dosage(BV)

Back Wash

Clean Water

2.0~4.0

1.5~2.0

Regenerate

3~5%HCl Solution

2.0~4.0

1.0~2.0

Replacement

Clean Water

1.0~1.5

1.5~2.5

Rinse

Clean Water

1.0~2.0

1.0~1.5

Flushing

Clean Water

10~15

3.0~5.0

Operating

Sugar Liquor

5~10

2.0~5.0

Sugar Recovery

Clean Water

2.0~4.0

30~60

Noted: When start to back wash, the flow rate should be slow, after all of the resins become flexible, increase back wash flow rate step by step, after resins are fully operating, stable back wash flow rate until the output water of back wash is clean.